Philips Respironics FiO₂ Sensor Assembly - Trilogy EV300

Item 1134668
Manufacturer: Philips Respironics
$440.00
or
Have insurance?

We can bill Medicare, Medicaid or your private plan instead of you paying now. Send a request and we will check what your plan covers before anything is ordered — there is no charge for asking.

Check my coverage
Ships anywhere in the US
We handle the insurance paperwork
Talk to a person, not a robot

About this product

Quick answer: This is the genuine Philips Respironics FiO₂ (oxygen) sensor assembly for the Trilogy EV300 ventilator (SKU 1134668). The FiO₂ sensor measures the fraction of inspired oxygen — the percentage of oxygen in the gas delivered to the patient — so the ventilator can monitor and report oxygen concentration. It's a consumable component with a limited service life and is replaced periodically or when it can no longer be calibrated. Clinician-directed use.

What's included

  • 1 × FiO₂ sensor assembly (SKU 1134668)

Ventilator, circuit, and other components not included.

About this part

When supplemental oxygen is delivered through a ventilator, the device needs to know how much oxygen the patient is actually receiving. The FiO₂ sensor provides that measurement — it reads the oxygen concentration in the delivered gas so the Trilogy EV300 can monitor it, display it, and alarm if it drifts outside the set range.

FiO₂ sensors are consumables by nature. Most oxygen sensors work by a chemical reaction that gradually depletes with exposure to oxygen over time — so even a perfectly functioning sensor eventually reaches the end of its service life and stops holding calibration. When that happens, the ventilator typically flags a calibration or sensor fault, and the sensor is replaced. Using the genuine Philips assembly ensures correct fit, calibration behaviour, and accuracy.

Key features

Specifications

Specification Detail
Product type FiO₂ (oxygen) sensor assembly
Compatible ventilator Philips Respironics Trilogy EV300
Function Measures fraction of inspired oxygen (FiO₂)
Type Consumable (limited service life)
Included Sensor assembly only
SKU 1134668
Prescription Clinician-directed
Brand Philips Respironics

Use & replacement notes

Install and calibrate the sensor exactly as described in the Trilogy EV300 clinical documentation, and only as part of a therapy managed by a clinical team. Replace the FiO₂ sensor when the ventilator indicates a sensor or calibration fault, when it can no longer be calibrated, or per the manufacturer's recommended service interval — whichever comes first. After installing a new sensor, run the calibration required by the device before returning the patient to monitored therapy. Store spare sensors per the manufacturer's instructions (sensor life can begin to count down once exposed to air, so check storage guidance).

Frequently asked questions

What does the FiO₂ sensor do? It measures the percentage of oxygen in the gas delivered to the patient, so the ventilator can monitor and alarm on oxygen concentration.

Which ventilator does it fit? The Philips Respironics Trilogy EV300.

Why do FiO₂ sensors need replacing? Most oxygen sensors deplete gradually with oxygen exposure, so they have a limited service life and eventually stop holding calibration — this is normal wear, not a defect.

How do I know it needs replacing? The ventilator typically flags a sensor or calibration fault, or the sensor can no longer be calibrated.

Do I need to calibrate after fitting it? Yes — run the calibration required by the Trilogy EV300 before returning to monitored therapy.

Do I need a prescription? Yes — ventilator components are used under clinical direction. Confirm your setup with your provider.

Can I get it delivered in Brooklyn or shipped nationwide? Yes — Task Supply Corp offers USPS shipping throughout the continental U.S., plus local pickup and delivery in Brooklyn and all five boroughs of New York City.

For use under clinical direction. Follow the Trilogy EV300 clinical documentation for installation, calibration, and replacement. Confirm oxygen monitoring is functioning correctly before returning the patient to monitored therapy.